Cabinets |
2 (1 main and 1 expansion cabinet) |
Power Supplies |
4 (2 per cabinet) |
Analog Trunks (CO/PBX lines) |
200 |
Digital Key Telephones |
256 (combined total to 256) |
Analog Single Line Telephones |
256 (combined total to 256) |
IP Telephones |
256 (in addition to the digital or analog ports) |
24-Button DLS Consoles |
256 |
110-Button DSS Consoles |
32 |
Conference Circuits |
64 (32 parties max per conference) |
ADA Adapter |
192 installs on a keyset |
APA Adapter |
192 installs on a keyset |
APR Adapter |
192 installs on a keyset |
CTA Adapter |
192 installs on a keyset |
CTU Adapter |
192 installs on a keyset |
IP Adapter |
256 installs on a keyset |
Power Failure Telephones |
30 provided by COIU PCBs |
2PGDAD Modules |
56 (48 for ACI ports, 4 for Door Boxes, 4 for Pages) |
Door Box/Door Unlock Contacts |
8 |
Internal Page Zones |
64 |
External Page Zones |
9 |
Dial Tone Detector Circuits |
64 (combined total to 64) |
DTMF Receiver Circuits |
64 (combined total to 64) |
|
|
Universal PCB slots |
Main Cabinet |
1-8 (not including NTCPU slot) |
Expansion Cabinet |
8-16 (Not including EXIFU slot) |
|
|
Aspire PCB Capacities |
NTCPU Central Processing Unit |
1 |
8ESIU 8 Digital Stations |
16 |
16ESIU16 Digital Stations |
16 |
8SLIU 8 Analog Stations |
15 |
8SLIDB 8 Analog Stations |
15 |
|
|
Daughter Board (installs on 8SLIU) |
16DSTU 16 i-Series Keyset Interface |
16 |
4COIU-LS1 4 Analog/Loop Start Trunks (no ground start) |
15 |
8COIU-LS1 8 Analog/Loop Start Trunks (no ground start) |
15 |
4COIU-LG1 4 Analog/Loop Start Trunks (with ground
start) |
15 |
8COIU-LG1 8 Analog/Loop Start Trunks (with ground start) |
15 |
2BRIU 2 Two-Channel BRI Circuits |
15 |
4BRIU 4 Two-Channel BRI Circuits |
15 |
8BRIU 8 Two-Channel BRI Circuits |
as T-Bus: 12; as S-Bus: 15 |
1PRIU 24 T1/PRI Trunks/Channels |
8 |
4TLIU 4 E&M Tie Line Trunks |
15 |
4DIOPU 4 DID/OPX Trunks |
15 |
4DIOPU 4 DID/OPX Trunks |
15 |
2FMSU 2 Flash Memory Voice Mail |
1 |
4FMSU 4 Flash Memory Voice Mail |
1 |
4VMSU 4 HDD Voice Mail |
1 |
4VMDB 4 HDD Voice Mail -Daughter Board |
1 |
UMSU Unified Messaging System |
1 |
8SHUBU 8 Switch Hub |
6 |
16VOIPU 16 VoIP Media Gateway |
6 |
|
|
16VOIPDB 16 VoIP Media Gateway |
Daughter Board (installs on 16VOIPU) |
6 |
APSU In-Skin Server without O/S |
2 per cabinet |
|
|
Environmental Specifications |
Cabinets, PCBs and Key Telephones |
Temperature: 0°C - 40°C (32 - 104°F) |
|
Humidity: 10-90% RH (non-condensing) |
|
NOTE: The VMSU-A1 and APSU-A1 are
exceptions. They are limited to +5°C - 40°C (41-104°F). |
Door Box |
Temperature: -20°C - 60°C (-4 - 140°F) |
|
Humidity: 20-80% RH (non-condensing) |
Power Supply |
Operating Temperature: 0°C - 40°C (32 - 104°F) |
|
Operating Humidity: 20-90% RH (non-condensing) |
|
Storage Temperature: -40°C - 75°C (-4 - 167°F) |
|
Storage Humidity: 10-95% RH (non-condensing) |
VMSU-A1/APSU-A1 PCBs |
Temperature: +5°C - 40°C (41-104°F). |
|
Humidity: 10-90% RH (non-condensing) |